3) E8500 INDUSTRIAL COMBUSTION ANALYSER

E8500 is used for combustion Gas & Emissions analysis in Boiler, Engine, Furnace & other combustion applications.

Feature :-

• Built In Thermo Electric Chiller
• Automatic Condensate Drain Pipe
• Wireless Remote Printer
• Draft & Differential Pressure Meter
• 2 channel Thermometer
• CO Dilution Auto Range
• True NOX measurement
• Upto 9 total Gas Sensors
• NDIR Sensors
• Gas Velocity Pitot Tube
• Rechargeable Batteries
• Internal Memory
• PC Software Package
• Bluetooth Module For PC
• Rotating Display with Zoom

 

PARAMETER SENSOR RANGE RESOULTION ACCURACY
O2 Electrochemical 0-25% 0.1% ±0.1% vol
CO Electrochemical 0-8000ppm 1 ppm 300ppm -±10 ppm Upto 2000ppm-±4% ,2000ppm-±10%
CO Autorange Electrochemical 0-20,000ppm 1ppm ±10% rdg
CO NDIR 0-15.00% 0.1% ±3% rdg
CO2 Calculated 0-99.9% 0.1%
C2H2 NDIR 0-5.00% 0.1% ±3% rdg
NO Electrochemical 0-4000ppm 1 ppm 125ppm -±5ppm) Upto 4000ppm-±4%
NO2 Electrochemical 0-1000ppm 1ppm 125ppm -±5ppm) Upto 1000ppm-±4%
NOX Calculated 0-5000ppm 1ppm
SO2 Electrochemical 0-4000ppm 1ppm 125ppm -±5ppm) Upto 4000ppm-±4%
Low NO and/or Low NO 2 Electrochemical 0-500ppm 1ppm 50ppm -±2ppm) Upto 500ppm-±4%
Tair Pt 100 -10 to 99.9 C 14.0 to 212.0 F 0.1 °C 0.1° F ±2 C° ±3 F°
Tgas TC K 0 to 999.9° C 32.0 to 1830.0° F 0.1 °C 0.1° F ±3 C° ±5 F°
?T Calculated 0-999.9 ° C 32.0 to 1830.0° F 0.1 °C 0.1° F
Pressure/Draft Bridge Bridge ±40.0 in H2O 0.1 in H2O ±1.0%rdg
Excess Air Calculated 1.00 - Infinity 0.1
Efficiency Calculated 1-99.9% 0.1 %
Gas Velocity 0-99.9m/s 0-330 ft/s 0.1m/s 0.1ft/s

Flue Gas Analysers Series