SLE-OGMC5
Special Features
1 Ambient gas monitoring and control
2 Active sampling for higher accuracy
3 Analog • Digital • Relay outputs
4 Large easy -to - read display
5 Alarm or Control options
6 Low maintenance
7 Easy to install
Applications
1 Ambient gas control
2 Ozone generator control
3 Alarm systems
Technical Specification
Sensor Type Analytical GSS Technology® Gas Sensitive Semiconductor
Ozone LOW sensor Range: 0 - 0.500 ppm ozone
Accuracy: <± 0.02 ppm
0 - 0.1ppm;<± 20% >0.1ppm
Max. exposure: 1 ppm
T90 response: <60 s
Thermocouple T/C sensor in SS 304 casing, length of inseration: 1 m with 2 m long cable
Sampling method Active sampling
Operational mode Continuous control or Alarm
Operating temperature/td> -5°C to 50°C
Operating relative humidity 5% to 95% non condensing
Warm up time 10 minutes (max. Accuracy)
Display 3.5 digit LCD
Relay set point User configurable
Digital output RS232
Analog output 0 - 5 VDC (8 bit)
Relay output (no internal alarm) 24 V; 5A (max.)
Alarm option (no relay output) Internal piezo 85 db @ 30cm
Power supply 12 VDC; 800 mA;
Plug - in AC power adaptor supplied
Enclosure rating IP20 & NEMA 1 equivalent
Enclosure dimensions 130 W x 94 H x 57 D (mm);
Enclosure casing Flame resistant thermoplast PS
Enclosure mounting Screw fix
Weight < 270 g; 9.5 oz
(excludes AC power adaptor)
Approvals Part 15 of FCC Rules
EN 61000 -6-3: 2001
EN 61000 -6-1: 2001