Xenon Test Chamber

• Full spectrum sunlight simulation
• Flat plate type test shelf with large size specimens
• Air-cooled for ultimate reliability and ease of maintenance
• Reproduces the damage caused by full-spectrum sunlight and rain.
• Full-featured weathering, light fastness and photo stability chamber at
• Precise control of critical test parameters including spectrum, irradiance, relative humidity, chamber temperature and black panel/black standard temperature.
• Xenon arc lamps give the best reproduction of full-spectrum sunlight.
• The irradiance control system continuously monitors and precisely maintains the irradiance set point by
• Automatically adjusting power to the lamps.
• Large specimen capacity

Technical Specifications

Chamber Type

Rotating Rack (1 time rotation/min)

Specimen Orientation (measured from horizontal)

90°

Full Spectrum Xenon Arc Lamps

1 pc × 1800 W (Water-cooling type)

Lamps standard quantity

2 pc (one is for use, the other is for reserve)

Lamp life

1600 ~ 1800 hours

Total exposure area

≥6000cm2

Radiation intensity

50-100w/m2

Wavelength

290 ~ 800nm

Irradiatometer

full spectrum light irradiatometer

340nm / 365nm monitoring point

Light filter

0% ≤ 255nm

90% in 400nm ~ 800nm

Trigger

Trigger time<2s

Water spray time

1~9999 minutes (adjustable)

Water spray pressure

0.12~0.15Mpa

Exposure / Water spray period

60min/12min/102min/18min adjustable

Black Panel Temperature range

63℃±3℃

Working room temperature range

RT+10℃~+80℃

Temperature fluctuation

≤±0.5℃

Temperature uniformity

≤±2.0℃

Relative Humidity function

65% ~ 98%R.H

Specimen Capacity and Size

90 specimens (each 75 × 150mm)

Water Consumption

≥20 Liter/hour

Internal size (W×H×D)

1000×1000×1000mm

Power

9.5KW

Constant Climate Chamber Series